Studies on Self-Testable/Self-Calibratable Capacitive Microaccelerometer with Metal Structure and High Load Capacity

LI Kai,CHEN Wenyuan,WANG Hong,CUI Feng,ZHANG Weiping
DOI: https://doi.org/10.3969/j.issn.1004-1699.2011.06.010
2011-01-01
Abstract:A novel microaccelerometer which can undergo high load is developed.In this microaccelerometer,the movable structure is composed of a circular plate and numbers of sector beams.By dividing the fixed electrode into two test electrodes and a driving electrode,the self-test and self-calibration functions are realizable.Key components of the microaccelerometer are made of metal,and the microaccelerometer is fabricated by UV-LIGA.Though there exists complex deformation on the fully compliant beam-plate structure and there exists complex electromechanical coupling in the microaccelerometer,an accurate and time-saving model is developed.A test on this device is processed based on AD7747,and it verifies the realizabilities of self-calibration of structure/material parameters and self-test of faults.
What problem does this paper attempt to address?