Design and experiment of high-overload capacitive micro-machined accelerometers

董景新 dong jingxin,刘云峰 liu yunfeng,陶永康 tao yongkang
DOI: https://doi.org/10.3788/OPE.20142204.0918
2014-01-01
Optics and Precision Engineering
Abstract:In consideration of the requirements of micro-machined accelerometers for enduring shock pulses in some special high-overload applications,a comb-finger capacitive closed-loop accelerometer with triaxial shock resistance was proposed.After analysis of the shock response of the closed-loop accelerometer with a stop,it points out that the flexible comb stop designed in the sensitive direction can reduce the impact force among the micro-structures and the modal separation and damping in the insensitive direction to strengthen the shock resistance in yand z axes can reduce the deformation and dissipate the shock energy.An impact hammer test demonstrates that the accelerometer can resist the acceleration shocks by 13,200g,and 102μs respectively,and the bias drifts is less than 5mV after shock.A prototype was designed and its nonlinearity is less than 500×10-6 in a full scale of±10g, its bias stability is 0.27mgfor 1.5h.The prototype can basically meet the demands of inertial measurements under high overload conditions.
What problem does this paper attempt to address?