A Study Of The Composition Of Ash Deposits In An Fbc System

Kl Liu,Wp Pan,Jt Riley,S Smith,K Ho,Kc Xie
1999-01-01
Abstract:Fireside deposits on heat transfer surfaces of boilers have been found both in the combustion chamber where the wall and screen tubes are subjected to radiant heat transfer and in the tube tanks of the convection passes. It is believed that molten alkali salts may cause severe corrosion when they deposit on the surfaces of heat exchange tubes in a boiler. The major advantage of the fluidized bed combustion (FBC) of fuels is its ability to absorb SO2 and HCl when limestone is used in the combustor. Unfortunately, more ash deposits are formed when limestone is used compared to combustion without sulfur sorbent. The combustion of high chlorine and high sulfur coal does generate some concerns about the possibility of chlorine-related corrosion of boiler components and ash deposits on heat-exchange surfaces at high temperatures. The knowledge of the distribution of sulfur and chlorine in ash under different conditions is necessary not only to understand the principle and efficiency of desulfurization by limestone, but also to evaluate the role of limestone in the capture of HCl.The ash deposits collected from different regions of an 0.3-meter (I.D.) bench FBC system were collected and analyzed after 1,000-hour burns with three separate coals. The major compound in the ash deposits is CaSO4. The concentrations of the major and minor elements in the various ash deposits were determined by ICP-AES spectrosocpy. The experimental results show that the operating temperature and the alkali contents have a major effect on the ash deposits.
What problem does this paper attempt to address?