PLASTIC LIMIT LOAD OF PRESSURIZED PIPING BRANCH JUNCTIONS UNDER COMBINED LOADINGS

轩福贞,李培宁,涂善东
DOI: https://doi.org/10.3321/j.issn:1001-9669.2003.06.012
2003-01-01
Abstract:For the accumulative rule of plastic limit load of pressurized piping branch junctions subjected to the combined loadings of internal pressure and moments, there are three different points of view, i.e., linear equation, parabolic equation and circular equation. In this work, such issue was investigated systemically by using the non-linear finite element method. According to the numerical results of fifty-four FE models, the accumulative rule of plastic limit load of piping tees with diameter ratio d/D≥0.5, under the combined loadings, is affected by the structural parameters (e.g., ratio of branch pipe diameter and run pipe diameter etc.), and does not conform to the linear equation, but strongly present a nonlinear behaviour such as parabolic equation and circular equation. Consequently, a novel formula that includes the effect of geometrical parameter was proposed to estimate the plastic limit load of tees under the combined loadings. To further verify the proposed formula, six experimental results of plastic limit load under the combined loadings were presented. Overall good agreement between the estimated values and the FE results as well as experimental data provides confidence in the use of the proposed formula in practice.
What problem does this paper attempt to address?