Study on a single-stage pulse tube with two-valve double-inlet configuration

GAN Zhi-Hua,Hua Zhao Liu,QIU Li-Min
2006-01-01
Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
Abstract:Two parallel-placed needle valves with opposite flow direction referred as two-valved configuration instead of traditional single-valved configuration as double-inlet are adopted to control DC flow and are proved to be a successful way to decrease the refrigeration temperature of a single-stage pulse tube cryocooler below 20 K. A single-stage G-M type pulse tube cryocooler with such two-valved double-inlet was presented in this paper. No load temperature 19.6 K and the cooling power 20.1 W at 39.2 K were reached, two-valved opening, frequency and other operation parameters of this cryocooler were discussed as well.