Simulation and experimental study of pulse tube cooler driven by thermoacoustic engine
LI Zhuo-pei,QIU Li-min,LIU Guo-jun,Bo Wang,HU Jin-qin
DOI: https://doi.org/10.3785/j.issn.1008-973X.2009.08.020
2009-01-01
Abstract:The influences of frequency, pressure ratio, charging pressure and regenerator length on the refrigeration performance of the pulse tube cooler driven by thermoacoustic engine were numerically simulated based on the regenerator simulation software known as REGEN3.2. The lowest no-load temperature of the pulse tube cooler was expected to be 45 K according to the simulation. The effects of working fluid, pressure ratio, acoustic power output device, and regenerator length were investigated experimentally. Experimental results show that the performance of the pulse tube cooler driven by a thermoacoustic engine can be improved significantly by increasing the pressure ratio, decreasing the frequency and properly increasing the charging pressure, which agrees well with the simulation. A single stage Stirling-type pulse tube cooler, with helium as the working fluid, driven by a traveling wave thermoacoustic engine with nitrogen as the working fluid and with a Helmholtz resonator as both acoustic power output device and acoustic pressure amplifier, obtained a lowest no-load temperature of 65 K.