Design and primary experiments for a pneumatically driven split-Stirling cryocooler operating at hundred hertz range

Yuan Yuan,Wang Longyi,Song Yujing,Gan Zhihua,Wu Yinong
DOI: https://doi.org/10.3969/j.issn.1000-6516.2013.02.001
IF: 2.134
2013-01-01
Cryogenics
Abstract:Based on the software SAGE,a pneumatically driven Split-Stirling cryocooler operating at hundred hertz range was designed and the influence of some parameters on the cryocooler was discussed.The design was verified in some extent by using a commercial compressor to drive the cryocooler.The experimental results show that the cryocooler can reach a no-load temperature of 77.1 K and gain 0.28 W cooling power at 90.0 K,while running at 105 Hz and the charging pressure of 2.50 MPa.
What problem does this paper attempt to address?