Theoretical and Experimental Study on a Pulse Tube Cryocooler Driven with a Linear Compressor

Q. Cao,G. J. Liu,Z. P. Li,Y. Z. Wu,L. M. Qiu,J. M. Pfotenhauer
2008-01-01
Abstract:A single-stage Stirling-type pulse tube cryocooler (PTC) has recently been designed using the REGEN modeling software developed at NIST Boulder. REGEN 3.2. The REGEN-based approach is based on a finite difference method to solve the mass, energy, and momentum conservation equations, used to optimize the regenerator. The regenerator operates at a charge pressure of 2.0 - 2.5 MPa and a frequency of 60 Hz. According to the REGEN3.2 calculation, a regenerator with a length of 45 mm and a diameter of 15 mm is capable of providing a cooling power above 5 W. An inertance tube comprised of two sections is used to regulate the phase between the pressure and mass flow rate at the hot end of the pulse tube. Its geometry is based on a transmission line model, named INERTANCE, developed by Radebaugh of NIST. The single-stage pulse tube cryocooler built according to the above calculation achieved the lowest temperature of 57.0 K, and a cooling capacity of 5.0 W at 79.1 K. This performance agrees well with the design prediction. Furthermore, the object-oriented software Sage has been used to simulate the pulse tube cryo- cooler performance after running the experiment. The results compare well with the experiment and provide the opportunity for further optimization of the inertance tube.