A two-stage Stirling-type pulse tube cryocooler with a cold inertance tube

Z.H. Gan,B.Y. Fan,Y.Z. Wu,L.M. Qiu,X.J. Zhang,G.B. Chen
DOI: https://doi.org/10.1016/j.cryogenics.2010.03.007
IF: 2.134
2010-01-01
Cryogenics
Abstract:A thermally coupled two-stage Stirling-type pulse tube cryocooler (PTC) with inertance tubes as phase shifters has been designed, manufactured and tested. In order to obtain a larger phase shift at the low acoustic power of about 2.0W, a cold inertance tube as well as a cold reservoir for the second stage, precooled by the cold end of the first stage, was introduced into the system. The transmission line model was used to calculate the phase shift produced by the cold inertance tube. Effect of regenerator material, geometry and charging pressure on the performance of the second stage of the two-stage PTC was investigated based on the well known regenerator model REGEN. Experimental results of the two-stage PTC were carried out with an emphasis on the performance of the second stage. A lowest cooling temperature of 23.7K and 0.50W at 33.9K were obtained with an input electric power of 150.0W and an operating frequency of 40Hz.
What problem does this paper attempt to address?