The Study on a Gas-Coupled Two-Stage Stirling-Type Pulse Tube Cryocooler

X. L. Wu,L. B. Chen,X. S. Zhu,C. Z. Pan,J. Guo,J. J. Wang,Y. Zhou
DOI: https://doi.org/10.1088/1757-899x/278/1/012146
2017-01-01
IOP Conference Series Materials Science and Engineering
Abstract:A two-stage gas-coupled Stirling-type pulse tube cryocooler (SPTC) driven by a linear dual-opposed compressor has been designed, manufactured and tested. Both of the stages adopted coaxial structure for compactness. The effect of a cold double inlet at the second stage on the cooling performance was investigated. The test results show that the cold double-inlet will help to achieve a lower cooling temperature, but it is not conducive to achieving a higher cooling capacity. At present, without the cold double-inlet, the second stage has achieved a no-load temperature of 11.28 K and a cooling capacity of 620 mW/20 K with an input electric power of 450 W. With the cold double-inlet, the no-load temperature is lowered to 9.4 K, but the cooling capacity is reduced to 400 mW/20 K. The structure of the developed cryocooler and the influences of charge pressure, operating frequency and hot end temperature will also be introduced in this paper.
What problem does this paper attempt to address?