Research of Stirling-Type Multi-Bypass Pulse Tube Cryocoolers with Temperatures below 20 K

Chen Liubiao,Zhou Qiang,Zhu Wenxiu,Xue Xiaodai,Wang Junjie,Zhou Yuan
DOI: https://doi.org/10.1063/1.4860812
2014-01-01
Abstract:Several Stirling-type pulse tube cryocoolers operating at liquid hydrogen temperatures for physical experiments have been designed, built and tested. For simplification and compactness, a single-stage configuration with a coaxial arrangement was employed. A multi-bypass configuration, together with a double-inlet and an inertance tube was adopted as the phase shifter, which resulted in the improved efficiencies. At present, typical cooling performance with a no-load temperature below 16 K and a cooling capacity over 1 W/30 K can be achieved with an input power less than 250 W. Some typical experimental results and considerations for achieving a better performance will be presented in this paper.
What problem does this paper attempt to address?