Performance of a Pulse Tube Cryocooler with Two Separate Stages using 3He in the Second Stage

Ning Jiang,Udo Lindemann,G.B. Chen,G. Thummes
2005-01-01
Abstract:This chapter presents the performance of a two-stage pulse tube cryocooler with 3He as the 2nd stage working fluid. This cooler consists of two pulse tube stages with separate gas supply. To save the amount of 3He, only the smaller second-stage is charged with 3He, while the first stage still operates with 4He as working fluid. A minimum no-load temperature of 1.27 K at the 2nd stage with the 1st stage at 23 K has been achieved by a present two-stage PTC, which is the lowest temperature obtained by regenerative cryocoolers up to now. At an input power of 1.49 kW to the 2nd stage, the cooler provides a maximum cooling power of 735 mW at 4.2 K with 3He. The cooler consists of two parallel separate pulse tube stages. The incoming gas to the second stage is precooled by a heat exchanger thermally connected to the cold end of the first stage. Compared to that of coolers with common gas supply, such design presents higher flexibility in distribution of cooling capacity of the stages and allows an easier adjustment of dc-flow. In addition, this arrangement makes possible to operate the two stages with different compressors and at different operating frequencies.
What problem does this paper attempt to address?