Experimental study on a three-stage cascade pulse tube cryocooler with transmission tube

Qinyu Zhao,Longyi Wang,Zhihua Gan,Zeyuan Jin
IF: 2.134
2017-01-01
Cryogenics
Abstract:To improve the cooling efficiency of pulse tube cryocooler(PTC),a well-designed transmission tube was introduced to recover the dissipated acoustic power at the warm end of the former PTC.The efficiency of the multi-stage cascade PTC was capable to approach Carnot efficiency.Based on this theory,a third PTC was connected in series with the existing two-stage cascade PTC.Experiments showed that the cooling power of the three-stage cascade PTC was 253.6W@233K,which was improved by 39.9% compared with that of the single-stage PTC.This moved the PTC's efficiency forward one more step to approach Carnot efficiency.