Abstract:A single-stage Stirling type pulse tube cryocooler(PTC)precooled by a two-stage GM type PTC was proposed to investigate the cooling performance of Stifling type PTC working at liquid helium temperature.Effect of regenerator length,regenerator matrix and working fluid on regenerator efficiency was investigated based on a regenerator simulation model known as REGEN 3.3. Cold inertance tube was used as the phase shifter in the Stirling type PTC to achieve better phase relationship between the mass flow and the pressure which greatly increases the efficiency of Stirling type PTC with small acoustic power input according to the calculation results.