Design and Preliminary Experimental Investigation of a 4 K Stirling-type Pulse Tube Cryocooler with Precooling

Zhi-hua Gan,Zhuo-pei Li,Jie Chen,Li Dai,Li-min Qiu
DOI: https://doi.org/10.1631/jzus.a0920095
2009-01-01
Abstract:A Stirling-type pulse tube cryocooler (PTC) with precooling was designed and manufactured to investigate its performance at 4 K. Numerical simulation was carried out based on the well-known regenerator model REGEN with an emphasis on the performance of a 4 K stage regenerator of the Stirling-type PTC as influenced by the warm end temperature, pressure ratio, frequency and average pressure with helium-4 and helium-3 as the working fluid respectively. This study demonstrates that the use of a cold inertance tube can significantly improve the efficiency of a 4 K Stirling-type PTC. A preliminary experimental investigation was carried out with helium-4 as the working fluid and a refrigeration temperature of 4.23 K was achieved. The experimental results show that the operating frequency has a significant influence on the performance of the Stirling-type PTC and a relatively low average pressure is favorable for decreasing the loss associated with the real gas effects of a 4 K Stirling-type PTC.
What problem does this paper attempt to address?