Therotical and experimental study on a 120 Hz single stage pulse tube cryocooler
GAN Zhi-hua,Yingzhe Wu,YUAN Yuan,Limin Qiu,ZHANG Xue-jun,ZHANG Xiao-bin,XU xu
DOI: https://doi.org/10.3785/j.issn.1008-973X. 2011.11.021
2011-01-01
Abstract:In order to study the characteristics of the high frequency regenerator and its influence to the performance of the pulse tube cryocooler,this paper optimized the geometry and operating parameters for the high frequency regenerator by using the numerical model,known as REGEN 3.2.A Stirling type pulse tube cryocooler operating at 120 Hz was designed,fabricated and tested.This cryocooler achieves a no-load temperature of 47.8 K,and can provide a cooling power of 8.0 W at 78.6 K.The result proves preliminarily that with higher frequency together with higher charging pressure,smaller hydraulic diameter and shorter regenerator,it is still possible to let the regenerator keep high efficiency.The experiment also indicated that this cryocooler can cool down fast and the pulse tube orientation effect was well suppressed benefiting from this higher frequency characteristic.