DC FLOW SUPPRESSION IN A SINGLE-STAGE G-M TYPE PULSE TUBE COOLER

THUMMES Guenter
DOI: https://doi.org/10.3969/j.issn.1005-1120.2004.04.007
2004-01-01
Abstract:An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of the cooler is experimentally examined. Two parallelplaced needle valves with an opposite flow direction called as double-valved configuration, instead of conventional single-valved configuration as the double-inlet is used to reduce the DC flow. With the double-valved configuration, the minimum temperatures of 18.4 K and 14.7 K,and the cooling powers of 11.5 W and 29. 5 W are also obtained by RW2 and CP4000, respectively.