Investigation on High-Performance Single-Stage GM-Type Pulse Tube Cooler

THUMMES Guenter
DOI: https://doi.org/10.3969/j.issn.1005-2615.2004.04.019
2004-01-01
Abstract:Experimental investigation on DC flow suppression and refrigeration characteristics of a high-performance single-stage GM-type pulse tube cooler has been undertaken. The influence of DC flow induced by the introduction of double-inlet on the refrigeration performance of the cooler is experimentally examined. Two parallel-placed needle valves with opposite flow direction called double-valved configuration, instead of conventional single-valved configuration as the double-inlet is successfully used in this experiment to reduce the DC flow. With a double-valved configuration, 18.4 K and 14.7 K (minimum temperature) are reached driven by RW2 and CP4000 compressor, respectively, and 11.5 W and 29.5 W (cooling power) at 30 K are obtained as well.