Study on Thermal Sensitivity of Waterwall in Once-through Boiler

WANG Wei-shu,BI Qin-cheng,ZHU Xiao-jing,MA Liang-dong,LIU Rui-lan,DONG Ying-bin
DOI: https://doi.org/10.3321/j.issn:1000-6761.2009.06.004
2009-01-01
Abstract:In the light of safety problem of boiler waterwall under disturbed conditions,quantitative calculation expression for thermal sensitivity coefficient of waterwall in once-through boiler was set up on the basis of separated flow model of liquid-gas two phase flow.A set of software for thermal sensitivity analysis of waterwall was developed by use of C++ Builder analyse program.The thermal sensitivity coefficient of waterwall in an 1 100 t/h once-through boiler was quantitatively calculated.The influence law of heat load,pressure,mass flow rate,etc.on sensitivity coefficients of flow rate,pressure drop as well as outlet enthalpy was analyzed.Results show that the influence of environmental disturbs on thermal sensitivity of boiler is the largest near the zone of critical pressure.The study results have significant sense for preventing waterwall from burst and ensuring safe operation of the once-through boiler.
What problem does this paper attempt to address?