Analysis of the Heating-surface Wall Temperature Characteristics of a CFB (circulating Fluidized Bed) Boiler Wing Wall

李燕,李文凯,吴玉新,杨海瑞
2009-01-01
Abstract:With the three wing wall typical structures of a circulating fluidized bed boiler serving as an example,namely,51×5mm,42×5mm and 38×5mm,analyzed was the influence of mass flow rate and parameters of the working medium on the wall temperature.It has been found that the mass flow rate is a dominant factor for securing a safe operation of the heating surfaces.The temperature difference between the wall surface and working medium decreases with an increase of the mass flow rate.The influence of the tubing structure and the outlet temperature of the working medium on the temperature difference between the wall surface and working medium is not evident,the influence of the tubing structure on the fin temperature,however,is relatively obvious.The pressure only affects the wall temperature to a certain extent.To consider both the safe and economic operation of a boiler at low loads,it is recommended that the design mass flow rate inside the wing wall heating surface should be chosen at a value not lower than 750 kg/m2·s.The research results can well provide reference for the safe operation of wing wall heating surfaces.