Steam and Water Wall Temperature of a 600mwe Supercritical Pressure Circulating Fluidized Bed Boiler

刘青,吕俊复,辛健,张建胜,岳光溪,于龙,张彦军,杨仲明
DOI: https://doi.org/10.3969/j.issn.1672-4763.2003.03.009
2003-01-01
Abstract:Supercritical pressure Circulating Fluidized Bed (CFB) is one of the clean and efficient coal combustion technology. The hydrodynamics of the vertical water wall of the furnace of the supercritical pressure CFB combustor under five loads were calculated in this paper. The results showed that DNB would not occurs within 60%~100% MCR. The highest temperature difference of the steam in the water wall outlet is 18℃, when the load is MCR, as well as the highest temperature of the pipe wall is 440℃, which is much less than the permission temperature of the water wall material.
What problem does this paper attempt to address?