An Analysis of Thermal Inertia of a CFB (Circulating Fluidized Bed) boiler

李金晶,李燕,吕俊复,岳光溪
2009-01-01
Abstract:The thermal inertia of a CFB (Circulating Fluidized Bed) boiler represents an important factor affecting the boiler dynamic characteristics. From the standpoint of a dynamic energy balance, defined was the thermal inertia of the CFB boiler. For boilers rated at 6 different capacities, calculated respectively were their thermal inertia magnitudes in various links of energy transfer. The calculation results show that the total thermal inertia magnitude of a boiler increases with an increase of its capacity, however, its unit evaporative capacity decreases with an increase of its capacity. Thermal inertia of a working medium and refractory materials constitutes a control link in the energy transfer process. As far as an economizer is concerned, metallic thermal inertia is of equal importance to that of a working medium. The thermal inertia of refractory materials in superheaters/reheaters is of the same magnitude order as the metallic thermal inertia. In water walls/panels, the working medium thermal inertia is considered as the biggest.