Heat Transfer in a Large-Scale Circulating Fluidized Bed Boiler

Cheng Leming,Wang Qinhui,Shi Zhenglun,Luo Zhongyang,Ni Mingjiang,Cen Kefa
DOI: https://doi.org/10.1007/s11708-007-0071-5
2007-01-01
Frontiers of Energy and Power Engineering in China
Abstract:Heat transfer of a furnace in a large-scale circulating fluidized bed (CFB) boiler was studied based on the analysis of available heat transfer coefficient data from typical industrial CFB boilers and measured data from a 12 MW e , a 50 MW e and a 135 MW e CFB boiler. The heat transfer of heat exchanger surfaces in a furnace, in a steam/water cooled cyclone, in an external heat exchanger and in the backpass was also reviewed. Empirical correlation of heat transfer coefficient was suggested after calculating the two key parameters, solids suspension density and furnace temperature. The correlation approach agrees well with the data from the large-scale CFB boilers.