Safety analysis of operation of water walls of a 300 MW once-through boiler in peak load operation

Hong Tang,Ruichang Yang,ZhongQi Lu,Deqiang Shi,Junkai Feng
1997-01-01
Abstract:The safety analysis of water walls of a 300MW once-through boiler in peak load operation is introduced. The boiler made in China is taking peak load operation, with quick variation of its loads. The authors analyzed the influence of deviation of combustion center on the safety of water walls at varying loads, including the deviation of heat absorption of water wall tubes at 300MW, 260MW, 240MW and 210MW. With the help of a computer, the deviations of flow rates in water wall tubes and the relevant tube wall temperatures were obtained. From the data collected, the conditions of burn out, or rupture of water wall tubes were obtained. Besides, the allowable deviation of combustion center was obtained. Thus, the measures to prevent tubes from burn out were obtained, the measures to make the boiler operate safely and reliably were also obtained.