Development of the Design of a 600 MW Low Mass Flow Speed Supercritical Pulverized Coal-fired Boiler with a Vertical Tube Coil

Hai Zhang
2014-01-01
Abstract:Analyzed were commonly seen specific features of several water wall arrangement modes of supercritical pulverized coal-fired boilers,tangentially and wall opposed combustion modes and principles for choosing the key parameters of a vertical tube coil water wall and designed and developed was a low mass flow speed vertical tube coil 600 MW supercritical pulverized coal-fired boiler. Under the full load operating condition,the design mass flow speed of the water wall was 940 kg / m2 s. The version under discussion adopted the low mass flow speed vertical tube technology developed by the Siemens Company. In combination with such merits as simple in the structure of vertical water walls and the self-compensated characteristics of the working medium at a low mass flow speed,the throttle orifice was removed,thus avoiding the complex structure of both water walls and lower headers,and at the same time,eliminating the safety hazard as the tube walls have exceeded the allowable temperature,created by any clogging in the structure of the throttle orifice during operation. An intermediate mixing header was provided between the upper and lower water wall in the furnace to mix with the working medium coming from the lower part of the furnace and minimizing the temperature deviation at the working medium side caused by non-uniform heat absorption and difference in the structure of the furnace. Finally,the authors described the structure of the boiler under discussion and predicted its performance.