Measurement and Its Error Analysis of Heat Flux in Water Wall

张攀,杨石,李文凯,李燕,王启民,杨海瑞
DOI: https://doi.org/10.3969/j.issn.1005-006x.2008.05.006
2008-01-01
Abstract:The understanding of the heat flux distribution in water wall is the basis for the development of super critical circulating fluidized bed boiler.The heat flux of the water wall can be determined from the temperature difference between two certain points on the rear of wall.The relationship between the temperature difference and heat flux,heat transfer coefficient from the wall to the water within tube,bed temperature,and water temperature is numerically studied.And the error of the predicted heat flux of the water wall with this method is analyzed.Especially the effects of the measured temperature error caused by thermocouples position in the practical installation on the predicted heat flux are discussed.
What problem does this paper attempt to address?