Simulation and experimental investigation of single stage high power stirling-type pulse tube cryocooler
SUN Jiu-Ce,QIU Li-Min,GAN Zhi-Hua,SUN Da-Ming,Kai Fang,LIU Dong-Hui,Xiao Jiang
2012-01-01
Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
Abstract:In order to investigate the stubborn problems only related to high-power Stirling-type pulse tube Cryocoolers (PTCs), such as flow inhomogeneity, temperature inhomogeneity, and impedance matching between compressor and cooler, a high power Stirling-type PTC is designed based on Sage. Preliminary tests have been investigated. At 60 Hz of operating frequency, the lowest no-load refrigeration temperature of 56.9 K have been reached with 800 W input power under 1.9 MPa. The cooling power at 77 K is 41.2 W with 4 kW input power when the pressure is 2.0 MPa. There is still large gap between the experimental results and the simulation results. The significant temperature inhomogeneity has been observed during the preliminary tests, the maximum temperature difference around the middle of the regenerator could reach as high as 120 K.