Experimental Investigation of Hybrid Regenerator Fillings with High Thermal Conductance in High Power Pulse Tube Cryocoolers

SUN Jiu-Ce,QIU Li-Min,GAN Zhi-Hua,ZHANG Xue-Jun
2013-01-01
Journal of Engineering Thermophysics
Abstract:An in-housc made single-stage pulse-tube cryocooler with inline configuration of regenerator and pulse tube was optimized for high cooling power near 80 K.The cooler is driven by a 10 kW-class linear compressor with dual opposed pistons,and the regenerator is designed with a small length to diameter ratio.To overcome the losses caused by temperature inhomogeneity,the transverse heat conductance in the regenerator was increased by use of hybrid type fillings,where the stainless wire mesh was inserted together with materials with higher thermal conductance,such as copper and brass mesh.Using these types of regenerator fillings,the losses from streaming were significantly reduced and the minimum no-load temperature was lowered from 54 to 47.5 K.The mean pressure and frequency of the pressure oscillation were also optimized.Up to now,a cooling power of 298 W at 71 K is available with an input power of 8.9 kW.
What problem does this paper attempt to address?