Regenerator performance improvement of a single-stage pulse tube cooler reached 11.1 K

Limin Qiu,YongLin He,Zhihua Gan,Xiaobin Zhang,Guobang Chen
DOI: https://doi.org/10.1016/j.cryogenics.2006.09.004
IF: 2.134
2007-01-01
Cryogenics
Abstract:In order to improve the cooling performance of pulse tube cooler (PTC) at 20–40K, hybrid regenerators are often employed. In this paper a three-layer regenerator, which consists of woven wire screen, lead sphere and Er3Ni is optimized to enhance the cooling performance and explore the lowest attainable refrigeration temperature for a single-stage PTC. The efforts focus on the temperature range of 80–300K, where woven wire screens are used. Theoretical and experimental studies are carried out to study the metal material and the mesh size effect of woven wire screens on the performance of the single-stage G-M type PTC. A lowest no-load refrigeration temperature of 11.1K was obtained with an input power of 6kW. The PTC can supply 17.8W at 20 K and 39.4W at 30K, respectively.
What problem does this paper attempt to address?