A Single-Stage Pulse Tube Cooler Reached 12.6 K

LM Qiu,YL He,ZH Gan,GB Chen
DOI: https://doi.org/10.1016/j.cryogenics.2005.08.001
IF: 2.134
2005-01-01
Cryogenics
Abstract:A single-stage G-M type pulse tube cooler (PTC) was designed and tested to explore the lowest attainable refrigeration temperature and to further improve the cooling performance in the temperature range of 15–40K. The magnetic material Er3Ni was used as part of the regenerative material besides the phosphor-bronze and the lead so as to improve the efficiency of the regenerator. With an input power of 6kW, a lowest no-load refrigeration temperature of 12.6K was obtained, which is a new record for the single-stage PTC. The cooling capacity at 15–40K was also significantly improved, which may extend the application of the single-stage PTC for the cooling of superconductors and cryopumps.
What problem does this paper attempt to address?