Performance study of a single-stage pulse tube cooler below 13 K

HE Yong-Lin,QIU Li-Min,GAN Zhi-Hua,Jie Lu,Li Tang,CHEN Guo-Bang
2007-01-01
Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
Abstract:Regenerator is one of the key components of pulse tube cooler, and its efficiency can greatly influence the performance of pulse tube cooler. In this article the performance of a single-stage G-M type pulse tube cooler with lead spheres of different quality is tested and analyzed. With an input power of 6 kW, a lowest no-load temperature of 12.9 K, which is a new record for the single-stage pulse tube cooler, and a cooling power of 57.4 W at 40 K have been obtained using imported lead spheres. A lowest no-load temperature of 13.6 K and a cooling power of 54.4 W at 40 K have been obtained using homemade lead spheres.