Performance study on regenerator of G-M type single stage pulse tube cooler

Tang Li,Qiu Limin,He Yonglin,Gan Zhihua
DOI: https://doi.org/10.3969/j.issn.1000-6516.2006.04.001
IF: 2.134
2006-01-01
Cryogenics
Abstract:For further improvement of performance of single stage G-M type pulse tube cooler(PTC),the experiment and theory study was focused on the efficiency of regenerator at 80 K~300 K.Through analysis of heat penetration depth and thermal conductivity between stainless steel and phosphor bronze,the result shows that stainless steel screens have better refrigeration performance than phosphor bronze ones.Based on numerical simulation with REGEN3.2, the result also shows that proper increase of mesh number can be beneficial to refrigeration performance.After parameters of single stage G-M type PTC were optimized,a new refrigeration temperature record of 11.1 K was achieved.Meanwhile,the cooler had refrigeration power of 17.8 W at 20 K and 40.7 W at 30 K.
What problem does this paper attempt to address?