DC pollution flashover and rain flashover performance for composite post insulators at high altitudes

Feng Zhao,Fuzeng Zhang,Haolin Yang,Zhicheng Guan,Liming Wang
DOI: https://doi.org/10.3321/j.issn:1000-0054.2009.10.002
2009-01-01
Abstract:The pollution flashover and rain flashover of composite post insulators at high altitudes were evaluated for five types of composite insulators with different structures in natural high altitude(1 970 m) environment.The study shows that the pollution flashover voltage is significantly higher than the rain voltage for the same conditions.The voltage variations with the insulate profiles are regular in a fixed range with the increased shed overhang leading to higher flashover voltages.Larger spaces between the sheds increase the pollution flashover voltage while the rain flashover voltage first increase and then decrease.Both types of flashover voltages decrease significantly with increasing mandrel diameter.Therefore,the pollution insulation deterioration can be evaluated based on only the pollution flashover at high altitudes and the flashover voltage can be increased more than 25% by optimizing the shed parameters.