Experimental Investigation on Outdoor Insulation for Dc Transmission Line at High Altitudes

Fuzeng Zhang,Jie Zhao,Liming Wang,Zhicheng Guan
DOI: https://doi.org/10.1109/tpwrd.2009.2034889
IF: 4.825
2010-01-01
IEEE Transactions on Power Delivery
Abstract:This paper presents the results of a study on the contamination characteristics of porcelain, glass and composite insulators in natural high altitude areas (1970 m). The test used the solid layer method, in which a contaminant solution consisting of sodium chloride, kaolin powder and water was used to coat the insulator surfaces. The insulators were wetted by steam fog in fog chamber. The 50% withstand voltage (U-50%) was determined by the up-and-down method. Experimental results indicate that insulator profiles have a significant effect on the flashover voltages. The flashover voltages for bell-type porcelain insulator are higher than tri-shed porcelain insulator. The glass insulator with bigger spacing has a higher flashover voltage than that with smaller spacing. The flashover characteristics of composite insulators can be greatly improved for about 20% by optimizing the shed parameters. In addition, the suspension patterns (I-, V- and Y-string) also have a significant influence on the porcelain insulator flashover voltages. The Y-string configuration appears to lead to much lower flashover voltages than I- and V- string insulators. The flashover voltages for V- string insulators are influenced by the angle between two insulator strings. The flashover voltage for V- strings of 120 degrees is highest, which is higher than that of I- string for 7.5%.
What problem does this paper attempt to address?