Studies of 100 um-thick silicon strip detector with analog VLSI readout

T. Hotta,M. Fujiwara,T. Kinashi,Y. Kuno,M. Kuss,T. Matsumura,T. Nakano,S. Sekikawa,H. Tajima
DOI: https://doi.org/10.48550/arXiv.physics/9812034
1998-12-18
Abstract:We evaluate the performances of a 100 um-thick silicon strip detector (SSD) with a 300 MeV proton beam and a 90Sr beta-ray source. Signals from the SSD have been read out using a VLSI chip. Common-mode noise, signal separation efficiency and energy resolution are compared with those for the SSD's with a thickness of 300 um and 500 um. Energy resolution for minimum ionizing particles (MIP's) is improved by fitting the non-constant component in a common-mode noise with a linear function.
Instrumentation and Detectors,High Energy Physics - Experiment
What problem does this paper attempt to address?