Abstract:Herein, weaddressedtheleakdetection and calibrationinvolved in the rigid positivestandard leaks, fabricated by quartz glassdrilling and being capable of withstanding a high pressureup to 7 MPa, in thehelium test loop,a test platform for the high temperature helium-cooled nuclear reactor ( HTR) .The influence of thepressure difference, in 0.7~7.0 MPa range, was mathematically formulated with circular tube model, theoreticallycalculat-ed and experimentally evaluated in standard leak comparison method.The calculated and measured results show that in 1.00 ×10 -4 ~2.38 ×10 -7 Pa· m3/s range,the dependence of the leakage rate on the pressure difference can be well described with viscous-molecular flow theory and can be analytically approximated by in quadraticpolyno-mial fitting.We suggest that the results may be of much technological interest in calibration and detection of high pressure (0 Pa~7 MPa) leaks, especially for HTR.