SIMULATION AND ANALYSIS ABOUT WORN-OUT ON CONNECTING PIPE OF LOW-PRESSURE REHEATER FOR A BOILER OF 600 MW UNIT

李相鹏,高增梁,陈江,周昊,岑可法
DOI: https://doi.org/10.3969/j.issn.1002-3364.2009.02.015
2009-01-01
Abstract:By adopting three-dimentional model,the simulation and analysis of worn-out on connecting pipe bundle of low-pressure reheater nearby the furnace outlet suffured from gas-phase flow field distribustion,movement of flyash,and concentration distribution etc.in the flue duct of boiler concerning 600 MW unit have been carried out.Results show that the flue gas velocity,particle's concentration and average collision velocity of particles nearby the furnace outlet all are larger due to influence of solid-gas two-phase flow distribution in the flue duct,thereby,the velocity of wornout on connecting pipes of the low-pressure reheater is also larger.It is recommended to install wornout-resistant covers of 6 mm thickness onto the windward surface of horizontal I-shaped pipe bundle of the low-pressure reheater between bottom of the first row connecting pipe and the other connecting pipes,as well as installing wornout-resitant covers with 3 mm thickness onto the other remained parts.