Study on Stress Intensity of Welding Parts of Small Dlameter Tube to Reheater in Coal-burning Thermo-electric Factory with 200 MW Power

LIU Chao-feng,XU Bo-hou,BAO Rong-hao,QI Jun-qing,XU Pei-yuan,LIU Ya-li
DOI: https://doi.org/10.3969/j.issn.1672-4763.2006.02.008
2006-01-01
Abstract:The quality and safety of welding parts of small diameter tube of reheater in thermo-electric factory are vital.If the quality and safety are ignored,frequently halting boiler and making huge economic lost might be after beginning work.Three reasons of leakage of welding parts of reheater were introduced,including incorrect design,bad materials performances and severe conditions.Incorrect design was most important reason.The welding parts of small diameter tube of reheater in a thermo-electric factory were calculated by finite element methods.The finite element analysis model was put forward in this paper.The affection of tilting angle and thickness of welding parts to stress intensity factors were researched in this paper.The figures of stress intensity factors obtained in this paper were referenced by engineer.
What problem does this paper attempt to address?