Cause analysis of elbow crack for header's connecting tubes of boiler's reheater concerning 300 mw unit

LIU Fa-sheng,CHEN Gang,WU Qi-xing
DOI: https://doi.org/10.3969/j.issn.1002-3364.2007.10.019
2007-01-01
Abstract:The elbow behind micro-spray desuperheater of boiler no.2 in one power plant has cracked many times,seriously affecting operation of the unit.Through inspection of the pipes,analysis of coal quality,and cold-state test of the reheater,it is believed that the crack of elbow is a typical thermal fatigue crack,resulting from deviation of actual coal sort from the designed coal sort,and temperature deviation of flue gas at outlet of the furnace,thus,leading to overtemperature of the heating surface,and frequently putting desuperheating water into service.Based on these,measures and recommendations,such as retrofitting the secondary air into reverse tangential firing,enhancing the feed-water and steam quality,improving quality of furnace-incoming coal and atomizing effectiveness of the nozzles,etc.,have been put forward.
What problem does this paper attempt to address?