ANALYSIS OF TEMPERATURE FIELD AND THERMAL STRESS FOR EXTERNALLY CONNECTED PIPE SOCKETS OF REHEATER BY USING THE FINITE ELEMENT METHOD

俞自涛,洪荣华,胡亚才,范利武,岑可法
DOI: https://doi.org/10.3969/j.issn.1002-3364.2005.05.005
2005-01-01
Abstract:The temperature field and thermal stress of tee pipe sockets for exhaust pipes to atmosphere from reheater have been analyzed by using the finite element method, the data at time points of 50, 200, and 400 minutes after startup being discussed. It is found from the results that the main cause leading to crack on pipes is as follows: When condensed water in said pipes periodically flows back or overflows to the interior of externally connected pipes on reheater, making the corner welding seams where the thermal stress being concentrated to produce thermal fatigue.
What problem does this paper attempt to address?