Low-NOx combustion retrofitting and optimal adjustment tests for a 130 t/h CFB boiler
Jianjun CHEN,Junhu ZHOU,Zhanheng ZHU,Chenjie ZHAO
DOI: https://doi.org/10.3969/j.issn.1002-3364.2017.02.081
2017-01-01
Abstract:Directing against the prohlems occurred on No.5 CFB boiler of Hangzhou United Thermoelectric Co.,Ltd.,such as high Nox emissions which does not meet the requirements of ultra-low emission,low main steam temperature,high bed temperature and furnace outlet temperature,a low-Nox combustion retrofitting which includes adjusting the secondary air system,increasing the heating surface,adding the flue gas recirculation system and improving the SNCR system,has been carried out.It achieves the desired results successfully.At rated load,the final concentration of Nox emissions decreased from 100 mg/m3 to less than 50 mg/m3,the main steam temperature increased by 20 ℃ and reached the design temperature,the bed temperature and furnace outlet temperature dropped by 50 ℃,the amount of ammonia slip which can be controlled within 8 mg/m3 had a slight increase,the boiler efficiency was almost invariant.Moreover,further optimization test was conducted to solve the problem of high CO concentration after the air pre-heater.The results show that,in order to optimize the boiler operation,different amounts of flue gas recirculation should be chosen at different loads,simultaneously the upper secondary air damper opening degree should be 100%,the lower secondary air damper opening degree should be distributed like that the middle is large and the both sides are small.