TEST STUDY ON CONPREHENSIVE RETROFIT OF BOILER’S HEAT RECOVERY SURFACE

周永刚,杨立隆,赵阳,陈永辉,李文华,赵虹
DOI: https://doi.org/10.3969/j.issn.1002-3364.2005.09.014
2005-01-01
Abstract:Directing against the problem of somewhat higher exhaust gas temperature from boiler no 1 in Wenzhou PowerGeneration Co Ltd, a retrofitting scheme of suitably increasing the heating surface of lowtemperature superheater and of the main economizer has been put forward. After retrofitting, the exhaust gas temperature reduces 20℃, the boiler efficiency increasing 0.8 percentage point. According to annual operation hours to be 5000 h, and price of coal to be 320 yuan (RMB) per ton, the annual coalsaving can reach 2240 t, saving fuel cost valued at 0.72 million yuan (RMB), economic benefit being obvious.
What problem does this paper attempt to address?