Experiment-study of firing system retrofitting of 1025 t/h boiler in Xibaipo Power Plant
陈智超,焦书震,李争起,武永军,刘文献,孙宪江,刘永刚,盖建勇,赵天中
DOI: https://doi.org/10.3969/j.issn.1004-9649.2003.11.012
2003-01-01
Abstract:In order to ensure the successful retrofitting of lower layer burners of No. 1 boiler (1025 t/h) in Xibaipo Power Plant, the combustion adjustment and low load test were conducted. The experiment showed that, by employing bias combustion, swirl burners to replace the original lower layer burners, the boiler could operate stably at a load of 135 MW without auxiliary fuel oil hiring. At the rated load, when the rotational speeds of pulverized coal feeders for the lower layer and middle layer burners were about 570~600 rpm and the rotational speed of feeders for top layer burners was 450 rpm, the efficiency of boiler was higher than that with other rotational speeds; when the secondary air dampers at each row were 100% open, the efficiency of boiler was higher than that with other damper positions; and the efficiency of boiler with two mills running was higher than that with three mills running.