Application of the Primary Air Enriched Burner in a Solely Heshan-coal-fired Pulverized Coal Boiler

Hai ZHANG,Jun-fu LU,Xiu-qing XU,Xue-an WU,Zi-sheng BIN,Zhi-tao GAO,Guang-sheng LU
DOI: https://doi.org/10.3969/j.issn.1672-4763.2007.03.009
2007-01-01
Abstract:Heshan coal is one of the steam coals that are most difficult to burn in China.The retrofit of the unit NO.4 PC boiler with steam capacity of 400 t/h in Heshan Power Plant was successfully conducted with a specially-designed primary air enriched burner,F-J burner.After retrofit,combustion became stable while Heshan coal was solely burnt,and unburnt carbon in fly ash and bottom ash decreased to less than 3 % from 12 %.The boiler efficiency remarkably increased by 10 % to 90 %.No severe slugging and high temperature corrosion has been found on the heating surfaces.