Experimental research on the fire-carrying problems in primary air nozzle of 125 MW units
LIU Jing-yun,WENG Shan-yong,ZHOU Yong-gang,LING Bo-lin,YANG Jian-guo,ZHAO Hong
DOI: https://doi.org/10.3969/j.issn.1004-9649.2005.08.021
2005-01-01
Abstract:The safe operation of 125 MW units with hot-air conveying pulverized coal and centralized primary air is affected by the following problems such as fire-carrying in the primary air nozzle and slagging on the water-wall around burners etc. with the increasing of volatile and heat value. Generally, the pressurized cold air is added to prevent the fire-carrying, however, the exhaust gas temperature is increased by 15 ℃ or so than normal condition and the boiler efficiency reducing about 1%. Another effective way to eliminate fire-carrying is to use thick/thin phase burner to re-design the structure, with large circumferential, reducing the bluff body and adjusting the tangential of the primary incorporation. The practical application of #10 boiler in the TianShengGang Power Plant indicated that the fire-carrying problem was solved effectively without adding cold air, in spite of the volatile and heat value of the coal were somewhat increased, and the carbon fraction in fly ash and exhaust gas temperature decreased by 2.55% and 20.5 ℃ respectively, the boiler efficiency increased 2.69%. Based on this, the direct annual economic benefits will be more than 4 million, and the coal adaptability and stable combustion ability can be improved greatly.