Optimization adjustment of pulverizing system for a 600 MW unit boiler burning mixed inferior coal

LI Pei,LIANG Zengtong,Gao Zhengang,Li Shuaiying,ZHOU Yonggang,ZHAO Hong
DOI: https://doi.org/10.3969/j.issn.1002-3364.2013.05.064
2013-01-01
Abstract:Diagnosis and optimal adjustment tests for pulverizing system of a 600 MW unit boiler after using mixed inferior coal as the fuel was performed,and the unit comprehensive economy before and after the adjustment were compared.The results showed that,pretty small coal particle size and insufficient coal mill output were the major factors affecting the pulverizer's capacity.After the optimization,the coal mill capacity increased from ~50 t/h to above 65 t/h,indicating the coal mill capacity was dramatically improved and the unit realized running at full load condition.Although the slag carbon content had a slight increase,the boiler efficiency decreased by 0.27% and the standard coal consumption for power generation increased by 0.9 g/(kW·h),the electricity consumption of coal pulverizing per unit reduced by 17.4% and the standard coal consumption for power supply decreased by 2.4 g/(kW·h).The total economic benefit increased obviously.
What problem does this paper attempt to address?