Analyzing Factors of Unburned Coal in Fly Ash During Pulverized Coal Reburning

YANG Wei-juan,ZHOU Jun-hu,LIU Mao-sheng,ZHOU Zhi-jun,LIU Jian-zhong,HUANG Zhen-yu,CEN Ke-fa
DOI: https://doi.org/10.3321/j.issn:0258-8013.2006.18.021
2006-01-01
Abstract:A ruburning retrofit scheme of a 410t/h pulverized-coal (PC) boiler was designed. And a method to calculating combustion efficiency of PC group in changing oxygen concentration was brought forward. Applied the method to the boiler, the effects of reburning fuel ratio, excess air ratio (α) and reburning coal fineness on combustion process and unburned coal in fly ash (UBC) were analyzed. The results show that the scheme is fitting and UBC increases 1.04% compared with that of the current operation. The burnout zone should be higher than 7 meters and provide combustion time more than 1 second in order to gain high combustion efficiency. Small change of α of main zone, α of reburning zone and reburning fuel ratio affects UBC little through it affects combustion process. UBC increases evidently with α of burnout zone decreasing. UBC decreases exponentially with reburning PC fineness increasing. And reburning PC is finer, UBC increase is smaller.
What problem does this paper attempt to address?