Main Influencing Factor of Conventional Pulverized-Coal Reburning

周俊虎,刘茂省,周志军,杨卫娟,刘建忠,岑可法
DOI: https://doi.org/10.3785/j.issn.1008-973x.2008.10.019
2008-01-01
Abstract:The conventional pulverized-coal was reburned on a HG-410/9.8-YW15 boiler.The effect of the mass ratio of reburning fuel,the ratio of overfire air(OFA),the oxygen volume fraction at the furnace exit and the coal mill running condition on the reburning was studied.The conventional pulverized-coal reburning can markedly reduce the nitrogen oxide emission with little effect on the steam parameter and the boiler efficiency.When the mass ratio of reburning fuel is larger than 24%,its increasing has little effect on nitrogen oxide reduction.The nitrogen oxide emission can be reduced largely and the carbon mass fraction in the fly ash changes little by increasing the ratio of OFA.The oxygen volume fraction at the boiler exit has magnitude effect on both the nitrogen oxide emission and the carbon mass fraction in the fly ash;the optimal value of oxygen volume fraction is above 2.9%.The nitrogen oxide emission increases with the tertiary air increasing although the tertiary air is posed in the main combustion zone.The nitrogen oxide emission can be still controlled on a lower level when operating at low load by adopting the conventional pulverized-coal reburning.
What problem does this paper attempt to address?