Abstract:The conventional pulverized-coal reburning process was studied on a HG-410/9.8-YW15 boiler. The nitrogen oxide emission both with and without reburning technology was measured. The effect of the conventional pulverized-coal reburning on the efficiency of the boiler, the flame temperature and the slagging condition was analyzed. When operating at full load, the nitrogen oxide emission of the boiler with conventional pulverized-coal reburning fuel is 268mg/m3, which is 51% lower than that without reburning. When operating at 70% load, the nitrogen oxide reduction is higher, and can reach 57%. After using the conventional pulverized-coal reburning technology, the steam parameter and the cooling water flux of the boiler is normal, the carbon content in the fly ash is 2.33%, which has little effect on both the efficiency of the boiler and the utilization of the fly ash. The efficiency of the boiler increases for the operation with low oxygen concentration. The temperature in the main combustion zone is higher with reburning than without reburning, and it is favorable for the combustion stabilization. Above the reburning nozzle, the furnace temperature after with conventional pulverized-coal reburning is the same to that without it. The conventional pulverized-coal reburning technology has no effect on the flame stability at low load. A series of measurement for slagging prevention is used and the implement of the conventional pulverized-coal reburning brings no slagging problem.