Retrofitting of a Planar Separator Circulating Fluidized Bed Boiler

吕俊复,张建胜,刘青,岳光溪,黄兴华,刘国华,陈志,徐洪亮
DOI: https://doi.org/10.3321/j.issn:1000-0054.2003.06.017
2003-01-01
Abstract:A significant problem in first generation circulating fluidized bed (CFB) boilers in China in the early 1990s was that they could not be easily operated at design load because the collection efficiency of separators such as the planar flow separator was quite poor. The performance of a 75 t/h planar flow separator in a circulating fluidized bed (CFB) boiler was improved by replacing the planar flow separator with a watercooled square cyclone with a particle accelerating inlet. The heating surface was also adjusted to ensure the best performance, while the overall configuration and supporting frame were not changed. Subsequent operating experience showed that the retrofitted CFB boiler could operate at design load with a reasonable temperature distribution in the main circulating loop. Thus, such retrofitting of CFB boilers is an effective means of improving boiler performance.